POWER BACK DOOR MAIN SWITCH INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT POWER BACK DOOR MAIN SWITCH


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      6(MSE) - 9(MSW) Not pushed (on) Below 1 Ω
      6(MSE) - 9(MSW) Pushed (off) 10 kΩ or higher

      If the result is not as specified, replace the power back door main switch.

    2. Apply battery voltage to the connector and check the LED illumination.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → terminal 8(ILL+)

      Battery negative (-) → terminal 7(ILL-)

      Illuminates
      Table 1. Text in Illustration
      *a

      Component without harness connected

      (Power Back Door Main Switch)

      *b Not pushed (on)
      *c Pushed (off)