DESCRIPTION
w/ Multi-information Display:
The ODO/TRIP display of the meter changes each time the ODO/TRIP switch on the light control rheostat is pressed.
For more information about changing between displays, refer to the owner's manual.
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT)
Operate the intelligent tester according to the display and select Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| ODO/TRIP Change SW | Trip switch (ODO/TRIP switch) condition/ON or OFF | ON: Trip switch pushed OFF: Trip switch not pushed |
- |
| OK |
|---|
| Switch condition (ON/OFF) can be switched by actual operation. |
INSPECT LIGHT CONTROL RHEOSTAT (TRIP SWITCH)
Remove the light control rheostat (Click here).
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT AND BODY GROUND)
Disconnect the E8 ECU connector.
Disconnect the E9 switch connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
REPLACE COMBINATION METER ASSEMBLYClick here
REPLACE COMBINATION METER ASSEMBLYClick here
REPLACE LIGHT CONTROL RHEOSTATClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR