VANITY LIGHT INSPECTION


  1. INSPECT VISOR ASSEMBLY RH


    1. A01593EE03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (SW) - 1 (GND) Visor raised 10 kΩ or higher
      2 (SW) - 1 (GND) Visor lowered and mirror cover closed 10 kΩ or higher
      2 (SW) - 1 (GND) Visor lowered and mirror cover open Below 1 Ω

      If the result is not as specified, there may be a malfunction in the visor assembly.

  2. INSPECT VISOR ASSEMBLY LH


    1. A01593EE03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (SW) - 1 (GND) Visor raised 10 kΩ or higher
      2 (SW) - 1 (GND) Visor lowered and mirror cover closed 10 kΩ or higher
      2 (SW) - 1 (GND) Visor lowered and mirror cover open Below 1 Ω

      If the result is not as specified, there may be a malfunction in the visor assembly.