ENTRY LOCK AND UNLOCK SWITCH (for Front) INSPECTION

Tech Tips


  • Use the same procedures for the LH side and RH side.

  • The procedures listed below are for the LH side.


  1. INSPECT ENTRY LOCK AND UNLOCK SWITCH

    A0156K2E01

    1. Disconnect the connector.

    2. Remove the outside handle.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 (TRG-) - 3 (TRG+) Lock switch not pushed (OFF) 10 kΩ or higher
      1 (TRG-) - 3 (TRG+) Lock switch pushed (ON) Below 1 Ω

      • If the result is not as specified, replace the entry lock and unlock switch.