INSTALL NO. 1 TRANSFER INDICATOR SWITCH
Using a SST, install a new gasket and the indicator switch.
| 09922-10010 |
| without SST | ||
| 40 N*m | 408 kgf*cm | 30 ft.*lbf |
| with SST | ||
| 28 N*m | 283 kgf*cm | 20 ft.*lbf |
Rotate SST in the direction shown in the illustration.
Use a torque wrench with a fulcrum length of 300 mm (11.8 in.).
Connect the connector.
INSTALL REAR DIFFERENTIAL LOCK ACTUATOR PROTECTOR
Install the protector with the 2 nuts.
| 35 N*m | 357 kgf*cm | 26 ft.*lbf |
INSTALL DIFFERENTIAL PROTECTOR ASSEMBLY
Attach the protector with the bolt and nut.
| 15 N*m | 150 kgf*cm | 11 ft.*lbf |
Connect the 2 connector clamps and wire harness clamp.
Make sure the wire harness of the No. 4 transfer indicator switch fits inside the protector.