CENTER DIFFERENTIAL LOCK SWITCH INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT CENTER DIFFERENTIAL LOCK SWITCH


    1. A015BNYE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 (L) - 4 (CPU) Switch pressed and held Below 1 Ω
      Switch not pressed 100 kΩ or higher

      If the result is not as specified, replace the center differential lock switch.