PARK / NEUTRAL POSITION SWITCH INSPECTION


  1. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY

    A0157N0E01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (RB) - 5 (PL) Shift lever in P Below 1 Ω
      2 (RB) - 5 (PL) Shift lever not in P 10 kΩ or higher
      2 (RB) - 1 (RL) Shift lever in R Below 1 Ω
      2 (RB) - 1 (RL) Shift lever not in R 10 kΩ or higher
      2 (RB) - 7 (NL) Shift lever in N Below 1 Ω
      2 (RB) - 7 (NL) Shift lever not in N 10 kΩ or higher
      2 (RB) - 6 (DL) Shift lever in D or S Below 1 Ω
      2 (RB) - 6 (DL) Shift lever not in D or S 10 kΩ or higher
      3 (B) - 4 (L) Shift lever in P or N Below 1 Ω
      3 (B) - 4 (L) Shift lever not in P or N 10 kΩ or higher

      If the result is not as specified, replace the switch assembly.