VALVE BODY ASSEMBLY INSPECTION


  1. INSPECT SHIFT SOLENOID VALVE SR

    A0158XYE02

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Solenoid Connector (SR) - Solenoid Body (SR) 20°C (68°F) 11 to 15 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve SR connector

      • Battery negative (-) → Shift solenoid valve SR body

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE SLU

    A01599DE02

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of shift solenoid valve SLU - terminal 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 2

      • Battery negative (-) → Terminal 1

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  3. INSPECT SHIFT SOLENOID VALVE SL2

    A015726E13

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of shift solenoid valve SL2 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  4. INSPECT SHIFT SOLENOID VALVE SLT

    A01599DE03

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of shift solenoid valve SLT - terminal 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 2

      • Battery negative (-) → Terminal 1

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  5. INSPECT SHIFT SOLENOID VALVE SL1

    A015726E15

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of shift solenoid valve SL1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  6. INSPECT SHIFT SOLENOID VALVE S1

    A0157J7E01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Solenoid Connector (S1) - Solenoid Body (S1) 20°C (68°F) 11 to 15 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve S1 connector

      • Battery negative (-) → Shift solenoid valve S1 body

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  7. INSPECT SHIFT SOLENOID VALVE S2

    A0158XYE01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Solenoid Connector (S2) - Solenoid Body (S2) 20°C (68°F) 11 to 15 Ω
    2. Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve S2 connector

      • Battery negative (-) → Shift solenoid valve S2 body

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.