Click here

AUTOMATIC TRANSMISSION SYSTEM (for 1GR-FE), Diagnostic DTC:P2716

Click here
Click here Click here
DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Click here

DESCRIPTION

The shift solenoid valve SLT controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor. The ECM adjusts the current of the SLT solenoid valve to control the hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.

DTC Code DTC Detection Condition Trouble Area
P2716 An open or short is detected in the shift solenoid valve SLT circuit for 1 sec. or more while driving (1 trip detection logic).
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • ECM

Click here

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

Click here

WIRING DIAGRAM

Click here

INSPECTION PROCEDURE

Click here

PROCEDURE


  1. Click here

    INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. A015739E66

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      14 (SLT+) - 6 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      14 (SLT+) - Body ground Always 10 kΩ or higher
      6 (SLT-) - Body ground Always 10 kΩ or higher
      Table 1. Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)


  2. Click here

    CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A015CW9E81

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C45-9 (SLT+) - C45-8 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      C45-9 (SLT+) - Body ground Always 10 kΩ or higher
      C45-8 (SLT-) - Body ground Always 10 kΩ or higher
      Table 2. Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)


  3. Click here

    INSPECT SHIFT SOLENOID VALVE SLT


    1. A0155DIE05

      Remove the shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 2

      • Battery negative (-) → Terminal 1

      Valve moves and makes an operating noise
      Table 3. Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SLT)


  4. Click here

    REPAIR OR REPLACE TRANSMISSION WIREClick here

  5. Click here

    REPLACE ECMClick here

  6. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  7. Click here