AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) Back-up Power Source Circuit

DESCRIPTION

The back-up power source circuit for the air conditioning amplifier assembly is shown below. Power is supplied even after the ignition switch is turned off and is used for diagnostic trouble code memory, etc.

WIRING DIAGRAM

A0157GCE25

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY)


    1. A0155VME23
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Disconnect the E81 air conditioning amplifier assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      E81-21 (+B1) - Body ground Always 11 to 14 V

    NG
    OK