Click here

AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) IG Power Source Circuit

Click here
Click here Click here
DTC Code DTC Name
  IG Power Source Circuit
Click here

DESCRIPTION

The main power source is supplied to the air conditioning amplifier assembly when the ignition switch is turned to ON. The power source is used for operating the air conditioning amplifier assembly, servo motors, etc.

Click here

WIRING DIAGRAM

Click here

INSPECTION PROCEDURE

Note:

Inspect the fuses and relays for circuits related to this system before performing the following inspection procedure.

Click here

PROCEDURE


  1. Click here

    CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY AND BODY GROUND)


    1. A0155VME22

      Disconnect the E81 air conditioning amplifier assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      E81-1 (IG+) - Body ground Ignition switch off Below 1 V
      Ignition switch ON 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E81-14 (GND) - Body ground Always Below 1 Ω
      Table 1. Text in Illustration
      *a

      Rear view of wire harness connector

      (to Air Conditioning Amplifier Assembly)


  2. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  3. Click here

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLEClick here