AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System), Diagnostic DTC:B1429/29

DTC Code DTC Name
B1429/29 Rear Air Foot Duct Sensor Circuit on Front Passenger Side

DESCRIPTION

The air duct temperature sensor RH*1 or LH*2 (for front passenger side) detects the duct temperature and sends the appropriate signals to the air conditioning amplifier assembly.

DTC Code DTC Detection Condition Trouble Area
B1429/29 An open or short in the air duct temperature sensor RH*1 or LH*2 circuit.
  • Air duct temperature sensor RH*1

  • Air duct temperature sensor LH*2

  • Harness or connector (air duct temperature sensor RH)*1

  • Harness or connector (air duct temperature sensor LH)*2

  • Air conditioning amplifier assembly

Tech Tips

*1: for LHD

*2: for RHD

WIRING DIAGRAM

A0157WFE36
A0157WFE37

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (AIR DUCT TEMPERATURE SENSOR)


    1. Use the Data List to check if the air duct temperature sensor RH*1 or LH*2 (for front passenger side) is functioning properly.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Foot Duct Sensor (Rear P)

      Min.: -12.7°C (9.14°F)

      Max.: 76.55°C (169.79°F)

      Actual air duct temperature sensor (for passenger side) displayed

      Open in the circuit: -12.7°C (9.14°F)

      Short in the circuit: 76.55°C (169.79°F)

      Tech Tips

      *1: for LHD

      *2: for RHD

      OK
      The display is as specified in the normal condition.

    NG
    OK
  2. CHECK AIR DUCT TEMPERATURE SENSOR

    A015B58E01

    1. for LHD


      1. Remove the air duct temperature sensor RH Click here.

    2. for RHD


      1. Remove the air duct temperature sensor LH Click here.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (+) - 2 (-) at 10°C (50°F) 9.4 to 10.5 kΩ
      at 15°C (59°F) 7.5 to 8.3 kΩ
      at 20°C (68°F) 6.0 to 6.5 kΩ
      at 25°C (77°F) 4.5 to 5.2 kΩ
      at 30°C (86°F) 3.8 to 4.2 kΩ
      at 35°C (95°F) 3.1 to 3.4 kΩ
      at 40°C (104°F) 2.5 to 2.8 kΩ
      at 45°C (113°F) 2.0 to 2.3 kΩ
      at 50°C (122°F) 1.6 to 2.0 kΩ
      at 55°C (131°F) 1.3 to 1.6 kΩ
      at 60°C (140°F) 1.1 to 1.4 kΩ

      Note


      • Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.

      • When measuring the resistance, the sensor temperature must be the same as the ambient temperature.

      Tech Tips

      As the temperature increases, the resistance decreases (see the graph).

      If the resistance value is not as specified, replace the sensor.

      Result
      Result Proceed to
      OK A
      NG (for LHD) B
      NG (for RHD) C

    B
    C
    A
  3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT TEMPERATURE SENSOR)

    A01594ME06

    1. for LHD


      1. Disconnect the L12 sensor connector.

      2. Disconnect the E35 amplifier connector.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        E35-26 (TR4) - L12-1 (+) Always Below 1 Ω
        E35-12 (SG-9) - L12-2 (-)
        E35-26 (TR4) - Body ground Always 10 kΩ or higher
        E35-12 (SG-9) - Body ground
    2. A01594ME07

      for RHD


      1. Disconnect the K21 sensor connector.

      2. Disconnect the E35 amplifier connector.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        E35-25 (TR3) - K21-1 (+) Always Below 1 Ω
        E35-34 (SGND) - K21-2 (-)
        E35-25 (TR3) - Body ground Always 10 kΩ or higher
        E35-34 (SGND) - Body ground

    NG
    OK