LUMBAR SWITCH (for Power Seat) INSPECTION


  1. INSPECT LUMBAR SWITCH LH (for LHD)

    A0155PQE06

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (B) - 4 (H) Hold Below 1 Ω
      1 (R) - 2 (E2)
      1 (R) - 2 (E2) Off
      4 (H) - 5 (E2)
      1 (R) - 3 (B) Release
      4 (H) - 5 (E2)

      If the result is not as specified, replace the lumbar switch.

  2. INSPECT LUMBAR SWITCH RH (for RHD)

    A0158ISE01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (B) - 4 (H) Hold Below 1 Ω
      1 (R) - 2 (E)
      1 (R) - 2 (E) Off
      4 (H) - 5 (E)
      1 (R) - 3 (B) Release
      4 (H) - 5 (E)

      If the result is not as specified, replace the lumbar switch.