| Condition | Specified Condition |
|---|---|
| Valve opening temperature | 74 to 78°C (165 to 172°F) |
| Valve lift | 10 mm (0.394 in.) or more at 90°C (194°F) |
| Item | Specified Condition |
|---|---|
| Standard value (for brand-new cap) |
93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| Minimum standard value (after using cap) |
79 kPa (0.8 kgf/cm2, 11.4 psi) |