3UR-FE COOLING SERVICE DATA

Click here
Click here
Table 1. Coolant
With rear heater 16.2 liters (17.1 US qts, 14.3 Imp. qts)
Without rear heater 13.4 liters (14.2 US qts, 11.8 Imp. qts)
Table 2. Water Inlet with Thermostat
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10.0 mm (0.394 in.) or more at 95°C (203°F)
Table 3. Radiator Cap
Standard value (for brand-new cap)

93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)

Minimum standard value (after using cap)

79 kPa (0.8 kgf/cm2, 11.4 psi)

Table 4. Fin for blockage
300 mm (11.8 in.)

2942 to 4903 kPa (30.0 to 50.0 kgf/cm2, 427 to 711 psi)

500 mm (19.7 in.)

4903 to 7845 kPa (50.0 to 80.0 kgf/cm2, 711 to 1138 psi)