1VD-FTV FUEL SERVICE DATA

Fuel injector (w/o DPF) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.85 to 1.05 Ω
Fuel supply pump Suction control valve Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 1.9 to 2.3 Ω
Standard thrust clearance 0.05 to 0.30 mm (0.00197 to 0.0118 in.)
Common rail Fuel pressure sensor Standard resistance Tester Connection Condition Specified Condition
1 - 2 25°C (77°F) 16.4 kΩ or less
2 - 3 25°C (77°F) 3 kΩ or less
Pressure discharge valve (w/ DPF) Standard resistance 1 - 2 25°C (68°F) 0.96 to 1.16 Ω
Fuel filter Level warning switch Standard resistance Tester Connection Condition Specified Condition
1 - 2 Float upper end position Below 1 Ω
1 - 2 Float lower end position 1 MΩ or higher
Clogging switch Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) Below 1 Ω
Fuel temperature sensor Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.32 to 2.59 Ω
Fuel pump (for Double Tank Type) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.2 to 3.0 Ω
Fuel sender gauge assembly Standard resistance Tester Connection Condition Specified Condition
1 - 2 Float level is F (upper) 13.5 to 16.5 Ω
Float level is E (lower) 405.5 to 414.5 Ω
Fuel sender gauge assembly (for Fuel Sub Tank) Standard resistance Tester Connection Condition Specified Condition
2 - 3 Float level is F (upper) 12 to 18 Ω
Float level is E (lower) 405 to 415 Ω