Click here

CANISTER INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT CHARCOAL CANISTER


    1. A0158C1E02

      Visually check the canister for cracks or damage.

      Table 1. Text in Illustration
      *1 Port A
      *2 Port B
      *3 Port C
      A015DIT Air
    2. Blow compressed air at 5 kPa (0.05 kgf/cm2, 0.7 psi) into port A and check that air flows without resistance from port B and port C.

      If the result is not as specified, replace the canister.

    3. Apply a vacuum of 2 kPa (0.02 kgf/cm2, 0.3 psi) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that the vacuum does not decrease when port B is released.

      If the result is not as specified, replace the canister.

  2. Click here

    CLEAN FILTER IN CANISTER


    1. A015D8IE02

      Clean the filter by blowing compressed air at 5 kPa (0.05 kgf/cm2, 0.7 psi) into port A while holding port B closed.

      Table 2. Text in Illustration
      *1 Port A
      *2 Port B
      A015DIT Air
      Note:

      Do not attempt to wash the canister.