DISCHARGE FUEL SYSTEM PRESSURE
PRECAUTION
Note
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE INTAKE AIR SURGE TANK
DISCONNECT NO. 2 FUEL PIPE SUB-ASSEMBLY
Disconnect the No. 2 fuel pipe sub-assembly Click here.
REMOVE FUEL PRESSURE REGULATOR ASSEMBLY
Disconnect the vacuum hose.
Remove the 2 bolts and fuel pressure regulator.
Remove the O-ring from the fuel pressure regulator.