REMOVE CENTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
Remove the 2 clips.
| *1 | Protective Tape |
Apply protective tape to the areas shown in the illustration.
Insert a moulding remover as shown in the illustration.
Pull the center instrument cluster finish panel sub-assembly in the direction indicated by the arrow to disengage the 2 clips and 5 guides, and remove the center instrument cluster finish panel sub-assembly.
REMOVE ACCESSORY METER ASSEMBLY
Remove the 2 screws.
Pull the accessory meter assembly in the direction indicated by the arrow to disengage the 2 clips.
Disengage the clamp.
Disconnect each connector and remove the accessory meter assembly.