DESCRIPTION
The combination meter assembly receives signals from this circuit to adjust the illumination of the combination meter assembly. The combination meter assembly sets the illumination level based on the user operation of the light control rheostat switch in the trip switch.
Tech Tips
The meter illumination level can be adjusted by pressing the light control rheostat switch.
The meter illumination dims when the headlight dimmer switch assembly is turned to the tail or head position at night.
Setting the meter illumination to maximum brightness cancels the above dimming of the meter illumination.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING GTS (LIGHT CONTROL UP SWITCH, LIGHT CONTROL DOWN SWITCH)
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Check the values by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Light Control Up Switch | Light control rheostat up switch/OFF or ON | OFF: Light control rheostat up switch not pressed | - |
| ON: Light control rheostat up switch pressed | |||
| Light Control Down Switch | Light control rheostat down switch/OFF or ON | OFF: Light control rheostat down switch not pressed | - |
| ON: Light control rheostat down switch pressed |
| OK |
|---|
| The value displayed on the GTS changes with the actual light control rheostat switch operation. |
| NG |
|
INSPECT TRIP SWITCH Click here |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here
INSPECT TRIP SWITCH
| *a | Component without harness connected (Trip Switch) |
Remove the trip switch Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE TRIP SWITCH Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
Disconnect the H14 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here