GENERATOR REMOVAL


  1. PRECAUTION

    Note

    After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work Click here.

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  3. REMOVE RADIATOR ASSEMBLY

    Click here

  4. REMOVE V-BANK COVER SUB-ASSEMBLY


    1. A01G4T2

      Hold the front of the V-bank cover sub-assembly and raise it to disengage the 2 retainers on the front of the V-bank cover sub-assembly. Continue to raise the V-bank cover sub-assembly to disengage the retainer on the rear of the V-bank cover sub-assembly and remove the V-bank cover sub-assembly.

      Note

      Attempting to disengage both front and rear retainers at the same time may cause the V-bank cover sub-assembly to break.

  5. REMOVE V-RIBBED BELT

    Click here

  6. REMOVE GENERATOR ASSEMBLY


    1. A01G4GX

      Disconnect the connector.

    2. Remove the cap.

    3. Remove the nut and disconnect the wire harness.

    4. Remove the bolt and disconnect the wire harness clamp.

    5. A01G81H

      Remove the 2 bolts.

    6. Disconnect the wire harness clamp and remove the generator bracket.

    7. A01G6YW

      Remove the 2 bolts and generator assembly.