DESCRIPTION
When the remote touch switch knob is operated, the built-in 2-axis motors are controlled. The motors are used to provide feedback force for the knob according to the pointer operation displayed on the multi-display assembly.
INSPECTION PROCEDURE
PROCEDURE
REMOTE TOUCH SELF CHECK (REMOTE TOUCH SWITCH KNOB FEEDBACK FORCE GENERATION CHECK)
| *a | Switch Knob |
| *b | Control Direction |
| *c | Feedback Force |
Check the remote touch switch knob feedback force generated.
Move the remote touch switch knob up, down, right and left to check that feedback force is generated.
| OK |
|---|
| Feedback force is generated. |
Tech Tips
When the engine switch is turned on (ACC), feedback force is generated. When the engine switch is turned off, feedback force is not generated, and the remote touch switch knob will move freely.
| NG |
|
REPLACE REMOTE OPERATION BOARD Click here |
| OK |
|
REMOTE TOUCH SELF CHECK (FEEDBACK FORCE FUNCTION)
Check feedback force function
Move the pointer on the screen by operating the remote touch switch knob and check that the feedback force of the knob changes according to the screen being displayed and the pointer position.
Tech Tips
Refer to Remote Touch Outline for further information on remote touch switch knob feedback force generated according to the screen being displayed and the pointer position Click here.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
USE SIMULATION METHOD TO CHECK Click here |
| A |
|
REPLACE MULTI-MEDIA MODULE RECEIVER ASSEMBLY Click here