AUDIO AND VISUAL SYSTEM, Diagnostic DTC:B1579

DTC Code DTC Name
B1579 Voice Recognition Microphone Disconnected

DESCRIPTION

The radio receiver assembly and roof console box assembly (telephone microphone assembly) are connected to each other using the microphone connection detection signal lines.

This DTC is stored when a microphone connection detection signal line is disconnected.

DTC No. DTC Detection Condition Trouble Area
B1579 Telephone microphone signal is lost.
  • Roof console box assembly

  • Telephone microphone assembly

  • Radio receiver assembly

  • Harness or connector

WIRING DIAGRAM

A01G7RTE97

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT RADIO RECEIVER ASSEMBLY


    1. A01G922E05
      Text in Illustration
      *a

      Component with harness connected

      (Radio Receiver Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H179-19 (MIN-) - Body ground Always Below 1 Ω

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (RADIO RECEIVER ASSEMBLY - ROOF CONSOLE BOX ASSEMBLY (TELEPHONE MICROPHONE ASSEMBLY))


    1. Disconnect the H179 radio receiver assembly connector.

    2. Disconnect the T11 roof console box assembly (telephone microphone assembly) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H179-19 (MIN-) - T11-2 (MCO-) Always Below 1 Ω
      H179-6 (SNS2) - T11-1 (SNS2) Always Below 1 Ω
      H179-19 (MIN-) - Body ground Always 10 kΩ or higher
      H179-6 (SNS2) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. INSPECT ROOF CONSOLE BOX ASSEMBLY (TELEPHONE MICROPHONE ASSEMBLY)


    1. Remove the roof console box assembly (telephone microphone assembly) Click here.

    2. A01G5WXE61
      Text in Illustration
      *a

      Component without harness connected

      (Roof Console Box Assembly (Telephone Microphone Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (MCO-) - 1 (SNS2) Always Below 1 Ω

    NG
    OK
  4. REPLACE TELEPHONE MICROPHONE ASSEMBLY


    1. Replace the telephone microphone assembly with a new or known good one Click here.

    2. Clear the DTCs Click here.

    3. Recheck for DTCs and check that no DTCs are output.

      OK
      No DTCs are output.

    NG
    OK