AUTOMATIC TRANSAXLE SYSTEM Transmission Control Switch Circuit

DESCRIPTION

When the shift lever is in S and it is moved toward "-" or "+", it is possible to select different shift ranges (1st through 6th ranges).

Moving the shift lever toward "+" increases the shift range by one, and moving the shift lever toward "-" decreases the shift range by one.

WIRING DIAGRAM

A01G73RE06

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. READ VALUE USING GTS (SPORT SHIFT SWITCH STATUS)


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Engine and ECT / Data List.

    5. In accordance with the display on the GTS, read the Data List.

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Sports Shift Up SW

      Sport shift up switch status/

      ON or OFF


      • ON: Continuously shift to "+" (up-shift)

      • OFF: Release "+" (up-shift)

      -
      Sports Shift Down SW

      Sport shift down switch status/

      ON or OFF


      • ON: Continuously shift to "-" (down-shift)

      • OFF: Release "-" (down-shift)

      -
      Result
      Result Proceed to
      Data display is not within Normal Condition range A
      Data display is within Normal Condition range B

    B
    A
  2. CHECK HARNESS AND CONNECTOR (BATTERY - TRANSMISSION CONTROL SWITCH)


    1. A01G5SWE10
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Transmission Control Switch)

      Disconnect the H33 transmission control switch connector from lower shift lever assembly.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      H33-4 (IG) - Body ground Engine switch on (IG) 11 to 14 V
      Engine switch off Below 1 V

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - BODY GROUND)


    1. A01G5SWE11
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Transmission Control Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H33-2 (E) - Body ground Always Below 1 Ω

    NG
    OK
  4. INSPECT LOWER SHIFT LEVER ASSEMBLY (TRANSMISSION CONTROL SWITCH)


    1. A01G5M5E20
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Control Switch)

      Measure the resistance between each terminal of the transmission control switch when the shift lever is moved to each position.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H33-4 (IG) - H33-5 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher
      H33-3 (SFTU) - H33-2 (E)

      Shift lever held in "+"

      (Up-shift)

      Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      H33-1 (SFTD) - H33-2 (E)

      Shift lever held in "-"

      (Down-shift)

      Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM)


    1. Reconnect the H33 transmission control switch connector.

    2. A01G63SE19
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the A64 ECM connector.

    3. Turn the engine switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A64-27 (S) - Body ground
      • Engine switch on (IG)

      • Shift lever in S, "+" or "-"

      11 to 14 V
      A64-27 (S) - Body ground
      • Engine switch on (IG)

      • Shift lever not in S, "+" or "-"

      Below 1 V
    5. Turn the engine switch off.

    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A64-42 (SFTU) - Body ground

      Shift lever held in "+"

      (Up-shift)

      Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      A64-43 (SFTD) - Body ground

      Shift lever held in "-"

      (Down-shift)

      Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher

    NG
    OK