RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
Start the engine.
Operate the cooler compressor under the conditions shown below:
| Item | Condition | Indicator |
|---|---|---|
| Operating Time | 3 minutes or more | - |
| Temperature setting | Max cool | - |
| Blower speed | High | |
| Engine | Idling | - |
| A/C switch | On | |
This causes most of the compressor oil from the various components of the A/C system to collect in the A/C compressor.
Tech Tips
It is not necessary to operate the cooler compressor if the A/C does not operate because of compressor lock, etc.
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
Tech Tips
Use the refrigerant recovery unit in accordance with the manufacturer's instruction manual.
REMOVE AIR CONDITIONER PRESSURE SENSOR
Disconnect the connector.
Using a 27 mm deep socket wrench, remove the air conditioner pressure sensor.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent the entry of moisture and foreign matter.