2AR-FE COOLING TORQUE SPECIFICATIONS

Water pump
Part Tightened N*m kgf*cm ft.*lbf
Water pump x Water inlet housing 21 214 15
Thermostat
Part Tightened N*m kgf*cm ft.*lbf
Water inlet x Water inlet housing 10 102 7
Cooling fan motor
Part Tightened N*m kgf*cm ft.*lbf

Code Mark X and F:

Fan shroud x cooling fan motor

2.6 26 23 in.*lbf

Code Mark R:

Fan shroud x cooling fan motor

3.9 40 35 in.*lbf

Code Mark X and F:

Fan shroud x No. 2 cooling fan motor

2.6 26 23 in.*lbf

Code Mark R:

Fan shroud x No. 2 cooling fan motor

3.9 40 35 in.*lbf
Fan x Cooling fan motor 6.3 64 56 in.*lbf
No. 2 Fan x No. 2 cooling fan motor 6.3 64 56 in.*lbf
Radiator
Part Tightened N*m kgf*cm ft.*lbf
Condenser assembly x Radiator assembly 6.0 61 53 in.*lbf
Upper radiator support sub-assembly x Body 13 127 9
Radiator reserve tank assembly x Fan shroud 7.0 71 62 in.*lbf