AUTOMATIC HIGH BEAM SYSTEM Automatic High Beam Switch Circuit

Click here
Click here
DTC Code DTC Name
  Automatic High Beam Switch Circuit
Click here

DESCRIPTION

The main body ECU (multiplex network body ECU) detects auto high beam switch signals.

The automatic high beam system can be turned on and off by operating the auto high beam switch.

Click here

WIRING DIAGRAM

Click here

CAUTION / NOTICE / HINT

Note:

If the main body ECU (multiplex network body ECU) is replaced, refer to Service Bulletin.

Click here

PROCEDURE


  1. Click here

    READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. Read the display on the GTS.

      Table 1. Main Body
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Auto High Beam Main Switch Auto high beam switch signal/ON or OFF

      ON: Auto high beam switch pressed

      OFF: Auto high beam switch not pressed

      -
      OK
      Normal conditions listed above are displayed.

  2. Click here

    INSPECT AUTO HIGH BEAM SWITCH


    1. Remove the auto high beam switch (Click here).

    2. Inspect the auto high beam switch (Click here).

      OK
      Auto high beam switch is normal.

  3. Click here

    CHECK HARNESS AND CONNECTOR (AUTO HIGH BEAM SWITCH - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))


    1. Disconnect the H7 auto high beam switch connector.

    2. Disconnect the H10 main body ECU (multiplex network body ECU) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H7-6 (+B) - H10-17 (AHBI) Always Below 1 Ω
      H7-6 (+B) - Body ground Always 10 kΩ or higher

    • OKClick here
    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR

  4. Click here

    CHECK HARNESS AND CONNECTOR (AUTO HIGH BEAM SWITCH - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H7-3 (E) - Body ground Always Below 1 Ω

    • OK

      REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)

    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR