Click here

LIGHTING SYSTEM Hazard Warning Switch Circuit

Click here
Click here
DTC Code DTC Name
  Hazard Warning Switch Circuit
Click here

DESCRIPTION

The combination meter assembly receives the hazard switch ON signal and controls the operation of the hazard warning lights.

Click here

WIRING DIAGRAM


Click here
  1. A0003GYE21
    Table 1.
    *a HZSW
    *b Radio Receiver Assembly (Hazard Switch)
    *c Combination Meter Assembly

    w/ Navigation System:

  2. A0003GYE16
    Table 2.
    *a HZSW
    *b Radio Receiver Assembly (Hazard Switch)
    *c Combination Meter Assembly

    w/ Audio and Visual System:

Click here

PROCEDURE


  1. Click here

    READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Combination Meter / Data List.

    5. Read the Data List according to the display on the GTS.

      Table 3. Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Hazard Flasher Switch Hazard switch signal/ON or OFF

      ON: Hazard switch on

      OFF: Hazard switch off

      -
      OK
      Normal conditions listed above are displayed.

  2. Click here

    INSPECT RADIO RECEIVER ASSEMBLY (HAZARD SWITCH)


    1. Remove the radio receiver assembly (hazard switch) (Click here).

    2. Inspect the radio receiver assembly (hazard switch) (Click here).


  3. Click here

    CHECK HARNESS AND CONNECTOR (RADIO RECEIVER ASSEMBLY (HAZARD SWITCH) - COMBINATION METER ASSEMBLY)


    1. w/ Navigation System:


      1. Disconnect the H13 combination meter assembly connector.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        H98-9 (HAZ) - H13-2 (HZSW) Always Below 1 Ω
        H98-9 (HAZ) - Body ground Always 10 kΩ or higher
        H97-12 (GND1) - Body ground Always Below 1 Ω
    2. w/ Audio and Visual System:


      1. Disconnect the H13 combination meter assembly connector.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        H178-4 (HAZ) - H13-2 (HZSW) Always Below 1 Ω
        H178-4 (HAZ) - Body ground Always 10 kΩ or higher
        H179-7 (GND1) - Body ground Always Below 1 Ω

    • OK

      REPLACE COMBINATION METER ASSEMBLY (Click here)

    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR