PROCEDURE
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).
Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| OK | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Power Window Regulator Motor Assembly LH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor gear |
If the result is not as specified, replace the power window regulator motor assembly LH.
Initialize the power window control system after installing the power window regulator motor and regulator assembly onto the door.
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).
Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| OK | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Power Window Regulator Motor Assembly RH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor gear |
If the result is not as specified, replace the power window regulator motor assembly RH.
Initialize the power window control system after installing the power window regulator motor and regulator assembly onto the door.