Click here

POWER WINDOW REGULATOR MOTOR(for Front Door) INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH


    1. A0007HVE16

      Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).

      Note:

      Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 10 (UP) within 1 second.

      Motor gear rotates clockwise

      1. Connect the positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 7 (DOWN) within 1 second.

      Motor gear rotates counterclockwise
      Table 1. Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly LH)

      *b Counterclockwise
      *c Clockwise

      • If the result is not as specified, replace the power window regulator motor assembly LH.

      Note:

      Initialize the power window control system after installing the power window regulator motor and regulator assembly onto the door.

  2. Click here

    INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH


    1. A00088XE14

      Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).

      Note:

      Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect the positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 10 (UP) within 1 second.

      Motor gear rotates counterclockwise

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 7 (DOWN) within 1 second.

      Motor gear rotates clockwise
      Table 2. Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly RH)

      *b Clockwise
      *c Counterclockwise

      • If the result is not as specified, replace the power window regulator motor assembly RH.

      Note:

      Initialize the power window control system after installing the power window regulator motor and regulator assembly onto the door.