AIRBAG SYSTEM SRS Warning Light Remains ON

DESCRIPTION

The SRS warning light is located on the combination meter assembly.

When the SRS is normal, the SRS warning light comes on for approximately 6 seconds after the power switch is turned from off to on (IG), and then goes off automatically.

If there is a malfunction in the SRS, the SRS warning light comes on to inform the driver of a problem.

When terminals TC and CG of the DLC3 are connected, the DTC is displayed by blinking of the SRS warning light.

The SRS is equipped with a voltage-increase circuit (DC-DC converter) in the airbag sensor assembly in case the source voltage drops.

When the auxiliary battery voltage drops, the voltage-increase circuit (DC-DC converter) functions to increase the voltage of the SRS to normal voltage. In addition, when the voltage drops, the SRS warning light will illuminate.

A malfunction in this circuit is not stored in the airbag sensor assembly. The SRS warning light automatically goes off when the source voltage returns to normal.

The signal to illuminate the SRS warning light is transmitted from the airbag sensor assembly to the combination meter assembly through the CAN communication system.

WIRING DIAGRAM

A0005F4E56

CAUTION / NOTICE / HINT

Note


  • After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK SRS WARNING LIGHT OPERATION


    1. Check the SRS warning light operation approximately 6 seconds after the power switch is turned on (IG).

      Result
      SRS Warning Light Illumination Proceed to
      Remains on A
      Goes off and then comes on again B

    B
    A
  2. CHECK AUXILIARY BATTERY VOLTAGE


    1. Measure the voltage of the auxiliary battery.

      Standard Voltage
      11 to 14 V

    NG
    OK
  3. CHECK CONNECTOR


    1. Turn the power switch off.

    2. Disconnect the cable from the negative (-) auxiliary battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.

    3. Check that the connector is properly connected to the airbag sensor assembly.

      OK
      The connector is properly connected.

      Tech Tips

      If the connector is not connected securely, reconnect the connector and proceed to the next inspection.

    4. Disconnect the H36 airbag sensor assembly connector.

    5. Check that the terminals of the connector are not damaged.

      OK
      The terminals are not deformed or damaged.

    NG
    OK
  4. CHECK WIRE HARNESS (AIRBAG SENSOR ASSEMBLY - BODY GROUND)


    1. A00052BE04
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Airbag Sensor Assembly)

      Connect the cable to the negative (-) auxiliary battery terminal.

    2. Turn the power switch on (IG).

    3. Operate all components of the electrical system (defogger, wipers, headlights, heater blower, etc.).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      H36-21 (IG2) - Body ground Power switch on (IG) 8 to 16 V
    5. Turn the power switch off.

    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H36-25 (E1) - Body ground Always Below 1 Ω
      H36-26 (E2) - Body ground Always Below 1 Ω

    NG
    OK
  5. CHECK SRS WARNING LIGHT


    1. Turn the power switch on (IG).

    2. Check the SRS warning light condition.

      OK
      After the primary check period, the SRS warning light goes off for approximately 10 seconds and turns back on.

      Tech Tips

      The primary check operates for approximately 6 seconds after the power switch is turned on (IG).


    OK
    NG
  6. CHECK CAN COMMUNICATION SYSTEM


    1. Use the GTS to check if the CAN communication system is functioning normally.

      Tech Tips


      • Refer to CAN Bus Check for the CAN communication system Click here.

      • The airbag sensor assembly is connected to the CAN communication system. Therefore, before starting troubleshooting, make sure to check that there is no trouble in the CAN communication system.

      Result
      Result Proceed to
      DTC is not output A
      DTC is output B

    B
    A
  7. CHECK AUXILIARY BATTERY VOLTAGE


    1. Measure the voltage of the auxiliary battery.

      Standard Voltage
      11 to 14 V

    NG
    OK
  8. CHECK CONNECTOR


    1. Turn the power switch off.

    2. Disconnect the cable from the negative (-) auxiliary battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.

    3. Check that the connector is properly connected to the airbag sensor assembly.

      OK
      The connector is properly connected.

      Tech Tips

      If the connector is not connected securely, reconnect the connector and proceed to the next inspection.

    4. Disconnect the H36 airbag sensor assembly connector.

    5. Check that the terminals of the connector are not damaged.

      OK
      The terminals are not deformed or damaged.

    NG
    OK
  9. CHECK WIRE HARNESS (AIRBAG SENSOR ASSEMBLY - BODY GROUND)


    1. A00052BE04
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Airbag Sensor Assembly)

      Connect the cable to the negative (-) auxiliary battery terminal.

    2. Turn the power switch on (IG).

    3. Operate all components of the electrical system (defogger, wipers, headlights, heater blower, etc.).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      H36-21 (IG2) - Body ground Power switch on (IG) 8 to 16 V
    5. Turn the power switch off.

    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H36-25 (E1) - Body ground Always Below 1 Ω
      H36-26 (E2) - Body ground Always Below 1 Ω

    NG
    OK
  10. CHECK CONNECTOR


    1. Disconnect the cable from the negative (-) auxiliary battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.

    2. Check that the connector is properly connected to the combination meter assembly.

      OK
      The connector is properly connected.

      Tech Tips

      If the connector is not connected securely, reconnect the connector and proceed to the next inspection.

    3. Disconnect the H14 combination meter assembly connector.

    4. Check that the terminals of the connector are not damaged.

      OK
      The terminals are not deformed or damaged.

    NG
    OK
  11. CHECK WIRE HARNESS (COMBINATION METER ASSEMBLY - BODY GROUND)


    1. A0006G3E02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Connect the cable to the negative (-) auxiliary battery terminal.

    2. Turn the power switch on (IG).

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      H14-21 (IG+) - Body ground Power switch on (IG) 11 to 14 V
      H14-22 (B) - Body ground Always 11 to 14 V
    4. Turn the power switch off.

    5. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H14-30 (ES) - Body ground Always Below 1 Ω

    NG
    OK
  12. CHECK SRS WARNING LIGHT


    1. Disconnect the cable from the negative (-) auxiliary battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.

    2. Reconnect the H14 combination meter assembly connector.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. Check the SRS warning light condition.

      OK
      After the primary check period, the SRS warning light goes off for approximately 10 seconds and turns back on.

      Tech Tips

      The primary check operates for approximately 6 seconds after the power switch is turned on (IG).


    OK
    NG