CIGARETTE LIGHTER LIGHT INSPECTION

PROCEDURE


  1. INSPECT CIGARETTE LIGHTER BEZEL STAY (CIGARETTE LIGHTER LIGHT)


    1. A00054KE02
      Text in Illustration
      *a

      Component without harness connected

      (Cigarette Lighter Bezel Stay)

      Connect a positive (+) lead from the auxiliary battery to terminal 1 and a negative (-) lead to terminal 2.

    2. Check that the cigarette lighter light comes on.

      OK
      Cigarette lighter light comes on.

      If the result is not as specified, replace the cigarette lighter bezel stay.