Click here

BLIND SPOT MONITOR MAIN SWITCH INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY)


    1. A0005R8E04

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (B) - 4 (D) Blind spot monitor main switch is on (not protruding) Below 1 Ω
      1 (B) - 4 (D) Blind spot monitor main switch is off (protruding) 10 kΩ or higher
      Table 1. Text in Illustration
      *a

      Component without harness connected

      (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

      If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).

    2. Check that the switch indicator illuminates.


      1. A0005R8E06

        Apply auxiliary battery voltage to the blind spot monitor main switch (warning canceling switch assembly) connector and check operation of the blind spot monitor indicator, as shown in the table below.

        OK
        Connection Condition Specified Condition

        Auxiliary battery positive (+) → Terminal 1 (B)

        Auxiliary battery negative (-) → Terminal 5 (E)

        Blind spot monitor main switch is on (not protruding) Blind spot monitor indicator illuminates

        Auxiliary battery positive (+) → Terminal 1 (B)

        Auxiliary battery negative (-) → Terminal 5 (E)

        Blind spot monitor main switch is off (protruding) Blind spot monitor indicator not illuminate
        Table 2. Text in Illustration
        *a

        Component without harness connected

        (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

        If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).

    3. Check that the switch illuminates.


      1. A0005R8E05

        Apply auxiliary battery voltage to the blind spot monitor main switch (warning canceling switch assembly) and check that the switch illuminates.

        OK
        Connection Specified Condition

        Auxiliary battery positive (+) → Terminal 3 (ILL+)

        Auxiliary battery negative (-) → Terminal 2 (ILL-)

        Illuminates
        Table 3. Text in Illustration
        *a

        Component without harness connected

        (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

        If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).