Click here

ULTRASONIC SENSOR(for Front Side) INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT NO. 1 ULTRASONIC SENSOR


    1. A01W3DNE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (S) - 1 (E) Always 20 to 40 kΩ
      Table 1. Text in Illustration
      *a

      Component without harness connected

      (No. 1 Ultrasonic Sensor)

      If the result is not as specified, replace the No. 1 ultrasonic sensor.