| DTC Code | DTC Name |
|---|---|
| B14A2 | Driver Side Solar Sensor Short Circuit |
DESCRIPTION
The solar sensor (automatic light control sensor) is installed on the upper side of the instrument panel. It detects sunlight and creates a signal that is used for air conditioning control in AUTO mode. The output voltage from the solar sensor (automatic light control sensor) varies in accordance with the amount of sunlight. When the sunlight increases, the output voltage increases. As the sunlight decreases, the output voltage decreases. The air conditioning amplifier assembly detects changes in the output voltage from the solar sensor (automatic light control sensor).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B14A2 | Short in driver side solar sensor (automatic light control sensor) circuit |
|
WIRING DIAGRAM
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Solar Sensor (D Side) | Driver side solar sensor (automatic light control sensor) / Min.: 0 Max.: 255 |
Driver side solar sensor (automatic light control sensor) value increases as brightness increases | - |
| OK |
|---|
| The display is as specified in the Normal Condition column. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
Disconnect the J1 solar sensor (automatic light control sensor) connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| *a | Front view of wire harness connector (to Solar Sensor (Automatic Light Control Sensor)) |
CHECK HARNESS AND CONNECTOR (SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the H54 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
INSPECT SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR)
Remove the automatic light control sensor (solar sensor) (Click here).
Reconnect the J1 solar sensor (automatic light control sensor) connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the negative (-) lead to terminal 1 and the positive (+) lead to terminal 3 of the solar sensor (automatic light control sensor).
Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor (automatic light control sensor).
As the inspection light is moved away from the sensor, the voltage decreases.
| *a | Component with harness connected (Solar Sensor (Automatic Light Control Sensor)) |
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
REPLACE SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR) (Click here)
CHECK HARNESS AND CONNECTOR (MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) - SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR))
Disconnect the H10 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)
REPAIR OR REPLACE HARNESS OR CONNECTOR