| DTC Code | DTC Name |
|---|---|
| B1411/11 | Room Temperature Sensor Circuit |
DESCRIPTION
The room temperature sensor (cooler (room temp. sensor) thermistor) is installed in the instrument panel to detect the cabin temperature which is used to control the air conditioning system AUTO mode. The resistance of the room temperature sensor (cooler (room temp. sensor) thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the room temperature sensor (cooler (room temp. sensor) thermistor) and reads voltage changes due to changes in the resistance of the room temperature sensor (cooler (room temp. sensor) thermistor).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1411/11 | Open or short in room temperature sensor (cooler (room temp. sensor) thermistor) circuit |
|
WIRING DIAGRAM
| *a | Room Temperature Sensor (Cooler (Room Temp. Sensor) Thermistor) |
| *b | Air Conditioning Amplifier Assembly |
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Room temperature sensor (cooler (room temp. sensor) thermistor) / Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| OK |
|---|
| The display is as specified in the Normal Condition column. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| A |
|
INSPECT ROOM TEMPERATURE SENSOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR)
Remove the room temperature sensor (cooler (room temp. sensor) thermistor) Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (see the graph).
| *a | Component without harness connected (Room Temperature Sensor (Cooler (Room Temp. Sensor) Thermistor)) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Allowable Range |
| *e | Temperature (°C (°F)) |
| NG |
|
REPLACE ROOM TEMPERATURE SENSOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the H54 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |