Click here

AIR CONDITIONING SYSTEM, Diagnostic DTC:B14A9

Click here
Click here
DTC Code DTC Name
B14A9 Glass Surroundings Temperature Sensor Circuit
Click here

DESCRIPTION

The air conditioning amplifier assembly detects the temperature of the area near the windshield glass using this circuit. The air conditioning amplifier assembly applies voltage to the air conditioning thermistor assembly (glass surroundings temperature sensor). As the temperature of the area near the windshield glass rises, the resistance decreases. The air conditioning amplifier assembly detects the resistance change as the windshield glass surroundings temperature changes.

The glass surroundings temperature sensor is integrated with the air conditioning thermistor assembly.

DTC No. DTC Detection Condition Trouble Area
B14A9 Open or short in glass surroundings temperature sensor circuit
  • Air conditioning thermistor assembly (glass surroundings temperature sensor)

  • Harness or connector (Air conditioning thermistor assembly (glass surroundings temperature sensor - air conditioning amplifier assembly))

  • Air conditioning amplifier assembly

Tip:

The whole air conditioning thermistor assembly should be replaced if the glass surroundings temperature sensor is malfunctioning.

Click here

WIRING DIAGRAM

Click here

PROCEDURE


  1. Click here

    READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.

      Table 1. Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Glass Surroundings Temperature

      Glass surroundings temperature/

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Actual glass surroundings temperature is displayed -
      OK
      The display is as specified in the Normal Condition column.
      Result
      Result Proceed to
      NG A
      OK (When troubleshooting according to Problem Symptoms Table) B
      OK (When troubleshooting according to the DTC) C

  2. Click here

    INSPECT AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS SURROUNDINGS TEMPERATURE SENSOR)


    1. A00095VE08
      A0008Z8E09

      Remove the air conditioning thermistor assembly (glass surroundings temperature sensor) (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (SEG3) - 2 (TNG) 10°C (50°F) 5.92 to 6.09 kΩ
      1 (SEG3) - 2 (TNG) 15°C (59°F) 4.94 to 5.07 kΩ
      1 (SEG3) - 2 (TNG) 20°C (68°F) 4.20 to 4.29 kΩ
      1 (SEG3) - 2 (TNG) 25°C (77°F) 3.64 to 3.70 kΩ
      1 (SEG3) - 2 (TNG) 30°C (86°F) 3.19 to 3.26 kΩ
      1 (SEG3) - 2 (TNG) 35°C (95°F) 2.85 to 2.91 kΩ
      1 (SEG3) - 2 (TNG) 40°C (104°F) 2.58 to 2.64 kΩ
      1 (SEG3) - 2 (TNG) 45°C (113°F) 2.37 to 2.43 kΩ
      1 (SEG3) - 2 (TNG) 50°C (122°F) 2.21 to 2.26 kΩ
      1 (SEG3) - 2 (TNG) 55°C (131°F) 2.07 to 2.12 kΩ
      1 (SEG3) - 2 (TNG) 60°C (140°F) 1.97 to 2.01 kΩ
      Note:
      • Hold the sensor only by its connector. Touching the sensor may change the resistance value.

      • When measuring, the sensor temperature must be the same as the ambient temperature.

      Table 2. Text in Illustration
      *a

      Component without harness connected

      (Air Conditioning Thermistor Assembly (Glass Surroundings Temperature Sensor))

      *b Heat Conduction Sheet Part
      *c Resistance (kΩ)
      *d Temperature (°C (°F))

  3. Click here

    CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - GLASS SURROUNDINGS TEMPERATURE SENSOR)


    1. Disconnect the H54 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      T3-2 (TNG) - H54-7 (TNG) Always Below 1 Ω
      T3-2 (TNG) - Body ground Always 10 kΩ or higher
      T3-1 (SEG3) - H54-35 (SG-4) Always Below 1 Ω
      T3-1 (SEG3) - Body ground Always 10 kΩ or higher

    • OK

      REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR