Measure the resistance according to the value(s) in the table below.
| Standard Resistance |
Table 1. Slide Switch
| Tester Connection |
Condition |
Specified Condition |
| 2 - 11 |
Front |
Below 1 Ω |
| 5 - 8 |
| 2 - 11 |
Off |
| 5 - 11 |
| 2 - 8 |
Rear |
| 5 - 11 |
|
Table 2. Front Vertical Switch
| Tester Connection |
Condition |
Specified Condition |
| 1 - 8 |
Up |
Below 1 Ω |
| 6 - 11 |
| 1 - 11 |
Off |
| 6 - 11 |
| 1 - 11 |
Down |
| 6 - 8 |
|
Table 3. Lifter Switch
| Tester Connection |
Condition |
Specified Condition |
| 3 - 8 |
Up |
Below 1 Ω |
| 4 - 11 |
| 3 - 11 |
Off |
| 4 - 11 |
| 3 - 11 |
Down |
| 4 - 8 |
|
Table 4. Reclining Switch
| Tester Connection |
Condition |
Specified Condition |
| 1 - 10 |
Front |
Below 1 Ω |
| 6 - 10 |
| 8 - 10 |
| 9 - 11 |
| 9 - 11 |
Off |
| 10 - 11 |
| 3 - 9 |
Rear |
| 4 - 9 |
| 8 - 9 |
| 10 - 11 |
|
Table 5. Text in Illustration
| *1 |
Front Vertical Switch |
| *2 |
Slide Switch |
| *3 |
Lifter Switch |
| *4 |
Reclining Switch |
| *a |
Component without harness connected (Front Power Seat Switch LH) |
If the result is not as specified, replace the front power seat switch LH.