AIR CONDITIONING SYSTEM Back-up Power Source Circuit

Click here
Click here
DTC Code DTC Name
  Back-up Power Source Circuit
Click here

DESCRIPTION

The back-up power source circuit for the air conditioning amplifier assembly is shown below. Power is supplied even when the power switch is off. The power is used for diagnostic trouble code memory, etc.

Table 1. *1 from Auxiliary Battery *2 A/C-B *3 Air Conditioning Amplifier Assembly
Click here

WIRING DIAGRAM

Click here

CAUTION / NOTICE / HINT

Note:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Click here

PROCEDURE


  1. Click here

    CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AUXILIARY BATTERY)


    1. Disconnect the H54 air conditioning amplifier assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      H54-21 (B) - Body ground Power switch off 11 to 14 V

    • OKClick here
    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR

  2. Click here

    CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H54-14 (GND) - Body ground Always Below 1 Ω

    • OK

      PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR