Click here

ГЕНЕРАТОР (для моделей с номинальным током 100 A) ПРОВЕРКА

Click here
Click here
  1. Click here

    INSPECT GENERATOR BRUSH HOLDER ASSEMBLY


    1. A01ISIL

      Using a vernier caliper, measure the brush length.

      Standard exposed length
      9.5 to 11.5 mm (0.374 to 0.453 in.)
      Minimum exposed length
      4.5 mm (0.177 in.)

      If the brush length is less than the minimum, replace the generator brush holder assembly.

  2. Click here

    INSPECT GENERATOR ROTOR ASSEMBLY


    1. Check the resistance.


      1. A01ISZKE01

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Slip ring - Slip ring 20°C (68°F) 1.8 to 2.2 Ω
        Table 1. Text in Illustration
        *1 Slip Ring

        If the result is not as specified, replace the generator rotor assembly.

      2. A01IPHBE01

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Slip ring - Rotor core Always 10 MΩ or higher
        Table 2. Text in Illustration
        *1 Slip Ring
        *2 Rotor Core

        If the result is not as specified, replace the generator rotor assembly.

    2. Check each slip ring.


      1. Check that the slip rings are not rough or scored.

        If rough or scored, replace the generator rotor assembly.

      2. A01IQPUE02

        Using a vernier caliper, measure the diameter of the slip rings.

        Standard diameter
        14.2 to 14.8 mm (0.559 to 0.583 in.)
        Minimum diameter
        14.0 mm (0.551 in.)

        If the diameter is less than the minimum, replace the generator rotor assembly.

    3. A01IO4I

      Check that the bearing is not rough or worn, and that it rotates smoothly.

      If the bearing does not rotate smoothly, replace the generator rotor assembly.

  3. Click here

    INSPECT GENERATOR PULLEY WITH CLUTCH


    1. A01IQIDE04

      Hold the center of the generator pulley, and check that the outer ring turns counterclockwise and does not turn clockwise.

      Table 3. Text in Illustration
      *a Free
      *b Lock

      If the result is not as specified, replace the generator pulley with clutch.