HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A1A-517, P0A1A-809

Click here
Click here
DTC Code DTC Name
P0A1A-517 Generator Control Module
P0A1A-809 Generator Control Module
Click here

DESCRIPTION

For a description of the inverter (Click here).

If the generator inverter overheats, has a circuit malfunction or has an internal short, the inverter transmits this information to the MG ECU via the generator inverter fail signal line.

If an abnormal amount of current flows through the generator inverter, the MG ECU detects it and sends a signal to inform the hybrid vehicle control ECU assembly of the malfunction.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A1A 517 Generator inverter fail signal detection (overcurrent due to MG ECU malfunction) Inverter with converter assembly
809 Abnormal generator current value detection (MG ECU malfunction)
Click here

CAUTION / NOTICE / HINT

CAUTION:

  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    Tip:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

Click here

PROCEDURE


  1. Click here

    CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.

      Result
      Result Proceed to
      P0A7A-203 is not output. A
      P0A7A-203 is also output. B
      Note:
      • If P0A7A-203 is output, troubleshoot it first. After completing the troubleshooting for P0A7A-203, return to perform troubleshooting for this DTC.

      • Parts repaired or replaced during troubleshooting for P0A7A-203 do not need to be re-inspected in this diagnosis procedure.

    5. Turn the power switch off.


  2. Click here

    CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.

      Tip:
      • If P0A7A-203 was not output in step 1 of this diagnosis procedure, check Table 1 below.

      • If P0A7A-203 was output in step 1 of this diagnosis procedure, repair that DTC first, then check Table 2 below.

      Result
      Result Proceed to
      P0A1A-517 or 809 only is output, or DTCs except the ones in the table below are also output. A
      Any of the following DTCs are also output. B
      Table 1. Table 1
      DTC No. Relevant Diagnosis
      P06B0-163 Sensor Power Supply "A" Circuit/Open
      P06D6-511 Sensor Reference Voltage "F" Circuit/Open
      P06E6-164 Sensor Power Supply "C" Circuit/Open
      P0A1A-151, 166, 658, 791 Generator Control Module
      P0A1B-198, 786, 794 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0BEA-290 Drive Motor "A" Phase V Current Sensor Circuit Range/Performance
      P0BEE-298 Drive Motor "A" Phase W Current Sensor Circuit Range / Performance
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P0D2E-586 Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance
      P0D2F-266 Drive Motor "A" Inverter Voltage Sensor Circuit Low
      P0D30-267 Drive Motor "A" Inverter Voltage Sensor Circuit High
      P0E05-328 Generator Phase V Current Sensor Circuit Range/Performance
      P0E09-336 Generator Phase W Current Sensor Circuit Range/Performance
      P0E32-585 DC/DC Converter Voltage Sensor "A" Range/Performance
      P0E33-589 DC/DC Converter Voltage Sensor "A" Low
      P0E34-590 DC/DC Converter Voltage Sensor "A" High
      P1C2A-155 Generator A/D Converter Circuit
      P1C2B-192 Drive Motor "A" A/D Converter Circuit
      P1C2D-587 Hybrid Battery Voltage / DC/DC Converter Voltage Correlation
      P1C3C-294 Drive Motor "A" Phase V Current Sensor Correlation
      P1C3D-302 Drive Motor "A" Phase W Current Sensor Correlation
      P1C3E-333 Generator Phase V Current Sensor Correlation
      P1C3F-341 Generator Phase W Current Sensor Correlation
      P1C4A-288 Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance
      P1C4F-296 Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance
      P1C54-326 Generator Phase V Current Sensor Sub Circuit Range/Performance
      P1C59-334 Generator Phase W Current Sensor Sub Circuit Range/Performance
      P1C6D-501 Drive Motor "A" Phase V Current Sensor Offset Range/Performance
      P1C6E-502 Drive Motor "A" Phase W Current Sensor Offset Range/Performance
      P1C71-515 Generator Phase V Current Sensor Offset Range/Performance
      P1C72-516 Generator Phase W Current Sensor Offset Range/Performance
      P1C73-512 Sensor Standard Voltage "F" Circuit/Open
      P1CA6-156 Generator Control Module Malfunction
      P1CA7-193 Drive Motor Control Module Malfunction
      P1CAC-200 Generator Position Sensor Angle Malfunction
      P1CAD-168 Drive Motor "A" Position Sensor Angle Malfunction
      P1CAF-792 Generator Position Sensor REF Signal Cycle Malfunction
      P1CB0-795 Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
      P1CB2-793 Generator Position Sensor REF Signal Stop Malfunction
      P1CB3-796 Drive Motor "A" Position Sensor REF Signal Stop Malfunction
      P3133-659 Communication Error from Generator to Drive Motor "A"
      P3134-661 Communication Error from Drive Motor "A" to Generator
      Table 2. Table 2
      DTC No. Relevant Diagnosis
      P06B0-163 Sensor Power Supply "A" Circuit/Open
      P06D6-511 Sensor Reference Voltage "F" Circuit/Open
      P06E6-164 Sensor Power Supply "C" Circuit/Open
      P0A1A-151, 166, 658, 791 Generator Control Module
      P0A1B-198, 786, 794 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0BEA-290 Drive Motor "A" Phase V Current Sensor Circuit Range/Performance
      P0BEE-298 Drive Motor "A" Phase W Current Sensor Circuit Range / Performance
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P0D2E-586 Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance
      P0D2F-266 Drive Motor "A" Inverter Voltage Sensor Circuit Low
      P0D30-267 Drive Motor "A" Inverter Voltage Sensor Circuit High
      P0E32-585 DC/DC Converter Voltage Sensor "A" Range/Performance
      P0E33-589 DC/DC Converter Voltage Sensor "A" Low
      P0E34-590 DC/DC Converter Voltage Sensor "A" High
      P1C2A-155 Generator A/D Converter Circuit
      P1C2B-192 Drive Motor "A" A/D Converter Circuit
      P1C2D-587 Hybrid Battery Voltage / DC/DC Converter Voltage Correlation
      P1C3C-294 Drive Motor "A" Phase V Current Sensor Correlation
      P1C3D-302 Drive Motor "A" Phase W Current Sensor Correlation
      P1C3E-333 Generator Phase V Current Sensor Correlation
      P1C3F-341 Generator Phase W Current Sensor Correlation
      P1C4A-288 Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance
      P1C4F-296 Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance
      P1C6D-501 Drive Motor "A" Phase V Current Sensor Offset Range/Performance
      P1C6E-502 Drive Motor "A" Phase W Current Sensor Offset Range/Performance
      P1C73-512 Sensor Standard Voltage "F" Circuit/Open
      P1CA6-156 Generator Control Module Malfunction
      P1CA7-193 Drive Motor Control Module Malfunction
      P1CAC-200 Generator Position Sensor Angle Malfunction
      P1CAD-168 Drive Motor "A" Position Sensor Angle Malfunction
      P1CAF-792 Generator Position Sensor REF Signal Cycle Malfunction
      P1CB0-795 Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
      P1CB2-793 Generator Position Sensor REF Signal Stop Malfunction
      P1CB3-796 Drive Motor "A" Position Sensor REF Signal Stop Malfunction
      P3133-659 Communication Error from Generator to Drive Motor "A"
      P3134-661 Communication Error from Drive Motor "A" to Generator
      Tip:
      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0A1A-517 or P0A1A-809 may be stored due to a malfunction which also causes DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

    5. Turn the power switch off.


  3. Click here

    CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note:

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A00046KE03

      Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

      Note:

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      OK
      The connectors are connected securely and there are no contact pressure problems.
      Tip:

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    • OK

      REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)

    • NG

      CONNECT SECURELY