HYBRID CONTROL SYSTEM, Diagnostic DTC:P06B0-163, P06D6-511, P06E6-164, P0A1A-151, P0A1A-166, P0A1A-658, P0A1A-791, P0A1B-198, P0A1B-786, P0A1B-794, P1C2A-155, P1C2B-192, P1C73-512, P1CA6-156, P1CA7-193, P3133-659, P3134-661

DTC Code DTC Name
P06B0-163 Sensor Power Supply "A" Circuit / Open
P06D6-511 Sensor Reference Voltage "F" Circuit / Open
P06E6-164 Sensor Power Supply "C" Circuit / Open
P0A1A-151 Generator Control Module
P0A1A-166 Generator Control Module
P0A1A-658 Generator Control Module
P0A1A-791 Generator Control Module
P0A1B-198 Drive Motor "A" Control Module
P0A1B-786 Drive Motor "A" Control Module
P0A1B-794 Drive Motor "A" Control Module
P1C2A-155 Generator A/D Converter Circuit
P1C2B-192 Drive Motor "A" A/D Converter Circuit
P1C73-512 Sensor Standard Voltage "F" Circuit / Open
P1CA6-156 Generator Control Module Malfunction
P1CA7-193 Drive Motor Control Module Malfunction
P3133-659 Communication Error from Generator to Drive Motor "A"
P3134-661 Communication Error from Drive Motor "A" to Generator

DESCRIPTION

The MG ECU located in the inverter with converter assembly monitors its internal operation and it will store DTCs when it detects malfunctions. If any of the following DTCs are output, replace the inverter with converter assembly.

DTC No. INF Code DTC Detection Condition Trouble Area
P06B0 163 Sensor Power Supply "A" Circuit / Open Inverter with converter assembly
P06D6 511 Sensor Reference Voltage "F" Circuit / Open
P06E6 164 Sensor Power Supply "C" Circuit / Open
P0A1A 151 Generator Control Module
P0A1A 166 Generator Control Module
P0A1A 658 Generator Control Module
P0A1A 791 Generator Control Module
P0A1B 198 Drive Motor "A" Control Module
P0A1B 786 Drive Motor "A" Control Module
P0A1B 794 Drive Motor "A" Control Module
P1C2A 155 Generator A/D Converter Circuit
P1C2B 192 Drive Motor "A" A/D Converter Circuit
P1C73 512 Sensor Standard Voltage "F" Circuit / Open
P1CA6 156 Generator Control Module Malfunction
P1CA7 193 Drive Motor Control Module Malfunction
P3133 659 Communication Error from Generator to Drive Motor "A"
P3134 661 Communication Error from Drive Motor "A" to Generator

PROCEDURE


  1. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT