HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A0D-350, P0A0D-351

Info Added 2017-08-02

DTC Code DTC Name
P0A0D-350 High Voltage System Inter-Lock Circuit High
P0A0D-351 High Voltage System Inter-Lock Circuit High

DESCRIPTION


DTC No. INF Code DTC Detection Condition Trouble Are
P0A0D 350 Operating any of the safety devices with the vehicle stopped (ILK signal is ON) and turning the power switch on (IG)
  • Wire harness or connector

  • Power management control ECU

  • Service plug grip

  • Inverter with converter assembly

  • No. 4 engine wire

  • Upper inverter cover

351 Interlock signal line opens (ILK signal is ON) while the vehicle is being driven

WIRING DIAGRAM

A00077BE10

CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.

      Result
      Result Proceed to
      P0A0D only is output. A
      P0A1D is output B
    5. Turn the power switch off.


    B
    A
  2. CLEAR DTC


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Read and record the DTCs and freeze frame data.

    5. Clear the DTCs and freeze frame data.

    6. Turn the power switch off.


    NEXT
  3. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.

      Result
      Result Proceed to
      P0A0D-350 or P0A0D-351 is output again. A
      Neither P0A0D-350 or P0A0D-351 is output again. B
    5. Turn the power switch off.


    B
    A
  4. CHECK SERVICE PLUG GRIP

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check if the service plug grip is installed correctly.

      Tech Tips


      • For the removal and installation procedures Click here.

      • P0A0D-350 is also stored if the power switch is turned on (IG) with the service plug grip removed. Confirm the conditions when the malfunction occurred.


    NG
    OK
  5. CHECK UPPER INVERTER COVER (GENERATOR CABLE SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A000699

      Check if the upper inverter cover (generator cable side) of the inverter with converter assembly is installed correctly.

      OK
      The upper inverter cover (generator cable side) is installed correctly.

    NG
    OK
  6. CHECK UPPER INVERTER COVER (MOTOR CABLE SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A0003GX

      Check if the upper inverter cover (motor cable side) of the inverter with converter assembly is installed correctly.

      OK
      The upper inverter cover (motor cable side) is installed correctly.

    NG
    OK
  7. CHECK CONNECTOR COVER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A0004W1

      Check if the connector cover assembly of the inverter with converter assembly is installed correctly.

      OK
      The connector cover assembly is installed correctly.

    NG
    OK
  8. CHECK NO. 4 ENGINE WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A0006UA

      Check if the No. 4 engine wire (air conditioning harness) is connected correctly.

      OK
      The No. 4 engine wire (air conditioning harness) connector is connected correctly.

    NG
    OK
  9. CHECK POWER MANAGEMENT CONTROL ECU

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A14 inverter with converter assembly connector.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A0004ZCE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A14-16 (ILKI) - Body ground Power switch on (IG) 11 to 14 V

      Note

      Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Reconnect the A14 inverter with converter assembly connector.


    NG
    OK
  10. CHECK INVERTER WITH CONVERTER ASSEMBLY (INTERLOCK)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A14 inverter with converter assembly connector.

    3. A0007DNE03
      Text in Illustration
      *a

      Component without harness connected

      (Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A14-16 (ILKI) - A14-5 (ILKO) Power switch off Less than 10 Ω

      Note

      Do not remove the upper inverter cover, connector cover assembly and No. 4 engine wire.

    4. Reconnect the A14 inverter with converter assembly connector.


    NG
    OK
  11. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - BODY GROUND)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A14 inverter with converter assembly connector.

    3. Install the service plug grip.

    4. A0008MBE03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A14-5 (ILKO) - Body ground Power switch off Below 1 Ω
    5. Remove the service plug grip.

    6. Reconnect the A14 inverter with converter assembly connector.


    NG
    OK
  12. CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT)


    1. Check the connections of each connector.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.

    OK
    NG
  13. CHECK SERVICE PLUG GRIP

    CAUTION:

    Be sure to wear insulated gloves.


    1. Remove the service plug grip.

    2. A0009NVE01
      Text in Illustration
      *1 Service Plug Grip

      Check the condition of the service plug grip interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    3. Install the service plug grip.


    NG
    OK
  14. CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A0003VXE04
      Text in Illustration
      *1 Interlock Connector

      Check that the interlock connector at the service plug grip installation socket is connected correctly.

      OK
      The connector is connected correctly.

    NG
    OK
  15. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A14 inverter with converter assembly connector.

    3. Disconnect the g2 service plug connector.

    4. A0005O6E01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Front view of wire harness connector

      (to Service Plug Grip)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A14-5 (ILKO) - g2-1(ILK) Power switch off Below 1 Ω
    5. Reconnect the g2 service plug grip connector.

    6. Reconnect the A14 inverter with converter assembly connector.


    OK
    NG
  16. CHECK UPPER INVERTER COVER (GENERATOR CABLE SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A000699

      Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.

    3. A0005O9E01
      Text in Illustration
      *1 Upper Inverter Cover (Generator Cable Side)

      Check the condition of the upper inverter cover (generator cable side) interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    4. Install the upper inverter cover (generator cable side) to the inverter with converter assembly.


    NG
    OK
  17. CHECK UPPER INVERTER COVER (MOTOR CABLE SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A0003GX

      Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.

    3. A0005O9E01
      Text in Illustration
      *1 Upper Inverter Cover (Motor Cable Side)

      Check the condition of the upper inverter cover (motor cable side) interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    4. Install the upper inverter cover (motor cable side) to the inverter with converter assembly.


    NG
    OK
  18. CHECK CONNECTOR COVER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A0004W1

      Remove the connector cover assembly from the inverter with converter assembly.

    3. A0006EBE01
      Text in Illustration
      *1 Connector Cover Assembly

      Check the condition of the connector cover assembly interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.

      Tech Tips

      The connector cover assembly is not available as a supply part. If it requires replacement, replace the inverter with converter assembly.

    4. Install the connector cover assembly to the inverter with converter assembly.


    NG
    OK
  19. CHECK NO. 4 ENGINE WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A0006UA

      Disconnect the No. 4 engine wire (air conditioning harness) from the inverter with converter assembly.

    3. A0007T6E01
      Text in Illustration
      *1 No. 4 engine wire (air conditioning harness)

      Check the No. 4 engine wire (air conditioning harness) interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    4. Connect the No. 4 engine wire (air conditioning harness) to the inverter with converter assembly.


    OK
    NG
  20. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A14 inverter with converter assembly connector.

    3. Disconnect the A31 power management control ECU connector.

    4. A0009A5E01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A14-16 (ILKI) - A31-32 (ILK) Power switch off Below 1 Ω
    5. Reconnect the A31 power management control ECU connector.

    6. Reconnect the A14 inverter with converter assembly connector.


    OK
    NG