HEATED OXYGEN SENSOR INSTALLATION

PROCEDURE


  1. INSTALL HEATED OXYGEN SENSOR


    1. A0006RUE04
      Text in Illustration
      *a

      Fulcrum Length

      30 mm

      *b

      Fulcrum Length

      300 mm

      Using SST, install the heated oxygen sensor to the front exhaust pipe.

      SST
      09224-00010
      Torque:
      without SST
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }
      with SST
      40 N*m  { 408 kgf*cm, 30 ft.*lbf }

      Note


      • The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.) and a torque wrench with a fulcrum length of 300 mm (11.8 in.) Click here

      • The "with SST" torque value is effective when SST is parallel to the torque wrench.

    2. Connect the heated oxygen sensor connector.

  2. INSPECT FOR EXHAUST GAS LEAK