HYBRID / BATTERY CONTROL SERVICE DATA

Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard value (for brand-new cap) 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17.7 psi)
Minimum standard value (for used cap) 94 kPa (1.0 kgf/cm2, 13.6 psi)
Relay
Item Tester Connection Specified Condition

IGCT relay

Resistance

3 - 5

10 kΩ or higher

(Auxiliary battery voltage is not applied across terminals 1 and 2)

3 - 5

Below 1 Ω

(Auxiliary battery voltage is applied across terminals 1 and 2)

INV W/ PMP relay

Resistance

3 - 5

10 kΩ or higher

(Auxiliary battery voltage is not applied across terminals 1 and 2)

3 - 5

Below 1 Ω

(Auxiliary battery voltage is applied across terminals 1 and 2)

Hybrid Battery Junction Block

SMRB

Resistance

A-1 (+) - S2-1 (CBI)

10 kΩ or more

(Auxiliary battery voltage is not applied between terminals Q6-1 (SMRB) and Q6-2 (GND))

A-1 (+) - S2-1 (CBI)

Below 1 Ω

(Auxiliary battery voltage is applied between terminals Q6-1 (SMRB) and Q6-2 (GND))

Q6-1 (SMRB) and Q6-2 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)

SMRG

Resistance

f1-1 (-) - S3-1 (CEI)

10 kΩ or more

(Auxiliary battery voltage is not applied between terminals Q6-3 (SMRG) and Q6-2 (GND))

f1-1 (-) - S3-1 (CEI)

Below 1 Ω

(Auxiliary battery voltage is applied between terminals Q6-3 (SMRG) and Q6-2 (GND))

Q6-3 (SMRG) and Q6-2 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)

SMRP

Resistance

f1-1 (-) - S3-1 (CEI)

10 kΩ or more

(Auxiliary battery voltage is not applied between terminals Q6-4 (SMRP) - Q6-2 (GND))

f1-1 (-) - S3-1 (CEI)

28.5 to 31.5 Ω

(Auxiliary battery voltage is applied between terminals Q6-4 (SMRP) - Q6-2 (GND))

Q6-4 (SMRP) - Q6-2 (GND) 112 to 274 Ω at -40 to 80°C (-40 to 176°F)
Integration Control and Panel Assembly

ECO mode switch

Resistance

4 (ECU) - 5 (E)

Below 10 Ω

(ECO mode switch being turned and held at ECO position)

10 kΩ or more

(ECO mode switch not turned)

NORMAL mode switch

Resistance

2 (B) - 5 (E))

Below 10 Ω

(NORMAL mode switch being pushed and held)

10 kΩ or more

(NORMAL mode switch not pushed)

SPORT mode switch

Resistance

3 (P) - 5 (E)

Below 10 Ω

(SPORT mode switch being turned and held at SPORT position)

10 kΩ or more

(SPORT mode switch not turned)

EV drive mode switch

Resistance

1 (S) - 5 (E)

Below 10 Ω

(EV drive mode switch being pushed and held)

10 kΩ or more

(EV drive mode switch not pushed)

VSC off switch

Resistance

7 (+) - 5 (E)

Below 10 Ω

(VSC off switch being pushed and held)

10 kΩ or more

(VSC off switch not pushed)

Integration control and panel assembly illumination Auxiliary battery positive (+) → 8 (ILL+) Auxiliary battery negative (-) → 6 (ILL-) Illuminates
Service Plug Grip
Service plug grip - Below 1 Ω