Measure the resistance according to the value(s) in the table below.
Table 1. Text in Illustration
| *a |
Component without harness connected (Shift Lever Position Sensor) |
| Standard Resistance |
| Tester Connection |
Condition |
Specified Condition |
| 8 (+B) - 1 (D) |
Shift lever in D, S, "+" or "-" |
Below 1 Ω |
| Shift lever not in D, S, "+" or "-" |
10 kΩ or higher |
| 8 (+B) - 2 (N) |
Shift lever in N |
Below 1 Ω |
| Shift lever not in N |
4.2 to 5.2 kΩ |
| 8 (+B) - 3 (P) |
Shift lever in P |
Below 1 Ω |
| Shift lever not in P |
10 kΩ or higher |
| 8 (+B) - 4 (R) |
Shift lever in R |
Below 1 Ω |
| Shift lever not in R |
10 kΩ or higher |
| 8 (+B) - 5 (MJ) |
Always |
Below 1 Ω |
| 8 (+B) - 6 (FD) |
Shift lever in D, S, "+" or "-" |
Below 1 Ω |
| Shift lever not in D, S, "+" or "-" |
10 kΩ or higher |
| 8 (+B) - 9 (RV) |
Shift lever in R |
Below 1 Ω |
| Shift lever not in R |
10 kΩ or higher |
|
If the result is not as specified, replace the shift lever position sensor.