Click here

SHIFT LEVER POSITION SENSOR INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT SHIFT LEVER POSITION SENSOR


    1. A0007GUE03

      Measure the resistance according to the value(s) in the table below.

      Table 1. Text in Illustration
      *a

      Component without harness connected

      (Shift Lever Position Sensor)

      Standard Resistance
      Tester Connection Condition Specified Condition
      8 (+B) - 1 (D) Shift lever in D, S, "+" or "-" Below 1 Ω
      Shift lever not in D, S, "+" or "-" 10 kΩ or higher
      8 (+B) - 2 (N) Shift lever in N Below 1 Ω
      Shift lever not in N 4.2 to 5.2 kΩ
      8 (+B) - 3 (P) Shift lever in P Below 1 Ω
      Shift lever not in P 10 kΩ or higher
      8 (+B) - 4 (R) Shift lever in R Below 1 Ω
      Shift lever not in R 10 kΩ or higher
      8 (+B) - 5 (MJ) Always Below 1 Ω
      8 (+B) - 6 (FD) Shift lever in D, S, "+" or "-" Below 1 Ω
      Shift lever not in D, S, "+" or "-" 10 kΩ or higher
      8 (+B) - 9 (RV) Shift lever in R Below 1 Ω
      Shift lever not in R 10 kΩ or higher

      If the result is not as specified, replace the shift lever position sensor.