EXHAUST PIPE INSTALLATION

Click here
Click here

PROCEDURE


  1. Click here

    INSTALL FRONT EXHAUST PIPE ASSEMBLY


    1. A000790

      Using a vernier caliper, measure the free length of the compression spring.

      Standard 42.0 mm (1.65 in.)
      Minimum 40.5 mm (1.59 in.)
      Tip:

      If the length is less than the minimum, replace the compression spring.

    2. Fully insert a new gasket to the exhaust manifold converter sub-assembly.

    3. A0004P1E25

      Using a plastic hammer and wooden block, tap in the new gasket until its surface is flush with the exhaust manifold converter sub-assembly.

      Table 1. Text in Illustration
      *1 Exhaust Manifold Converter Sub-assembly
      *2 Wooden Block
      *3 Gasket
      Note:
      • Be sure to install the gasket in the correct direction.

      • Do not reuse the gasket.

      • Do not damage the gasket.

      • Do not push in the gasket by using the exhaust pipe when connecting it.

    4. Connect the front exhaust pipe assembly to the exhaust pipe support.

    5. Install the front exhaust pipe assembly with the 2 compression springs and 2 bolts.

      43 N*m 438 kgf*cm 32 ft.*lbf
      A0005POE01
      Tip:

      After the installation, check that the gaps between the flanges of the exhaust manifold converter sub-assembly and front exhaust pipe assembly are consistent front-to-rear and left-to-right.

      Table 2. Text in Illustration
      *1 Exhaust Manifold Converter Sub-assembly
      *2 Front Exhaust Pipe Assembly
      *3 Gasket
      *a Space between flanges: 8.5 mm (0.335 in.)
  2. Click here

    INSTALL CENTER EXHAUST PIPE ASSEMBLY


    1. Install a new gasket to the front exhaust pipe assembly.

    2. Connect the center exhaust pipe assembly to the exhaust pipe support.

    3. Install the center exhaust pipe assembly with the 2 nuts.

      43 N*m 438 kgf*cm 32 ft.*lbf
  3. Click here

    INSTALL TAIL EXHAUST PIPE ASSEMBLY


    1. A000790

      Using a vernier caliper, measure the free length of the compression spring.

      Standard 40.0 mm (1.57 in.)
      Minimum 38.5 mm (1.52 in.)
      Tip:

      If the length is less than the minimum, replace the compression spring.

    2. Fully insert a new gasket to the center exhaust pipe assembly.

    3. A0004P1E25

      Using a plastic hammer and wooden block, tap in the new gasket until its surface is flush with the center exhaust pipe assembly.

      Table 3. Text in Illustration
      *1 Center Exhaust Pipe Assembly
      *2 Wooden Block
      *3 Gasket
      Note:
      • Be sure to install the gasket in the correct direction.

      • Do not reuse the gasket.

      • Do not damage the gasket.

      • Do not push in the gasket by using the exhaust pipe when connecting it.

    4. Connect the tail exhaust pipe assembly to the 3 exhaust pipe supports.

    5. Install the tail exhaust pipe assembly with the 2 compression springs and 2 bolts.

      43 N*m 438 kgf*cm 32 ft.*lbf
      A0009E6E01
      Tip:

      After the installation, check that the gaps between the flanges of the center exhaust pipe assembly and tail exhaust pipe assembly are consistent front-to-rear and left-to-right.

      Table 4. Text in Illustration
      *1 Tail Exhaust Pipe Assembly
      *2 Center Exhaust Pipe Assembly
      *3 Gasket
      *a Space between flanges: 6.5 mm (0.256 in.)
  4. Click here

    INSTALL HEATED OXYGEN SENSOR

    Click here

  5. Click here

    INSPECT FOR EXHAUST GAS LEAK