CANISTER INSPECTION

PROCEDURE


  1. CHECK CHARCOAL CANISTER


    1. Inspect the ventilation of the charcoal canister.


      1. A01W2C2E02
        Text in Illustration
        *1 Port A
        *2 Port B
        *a Air

        Open the fuel tank cap, apply compressed air to port A and check that air flows out from port B.

        OK
        Air flows out from the port B.
    2. Inspect the check valve.


      1. A01W2L2E02
        Text in Illustration
        *1 Port A
        *2 Port B
        *a Air

        Open the fuel tank cap, close port A and apply compressed air to port B.

        OK
        Air does not flow at first. By gradually increasing the pressure, air flows when the pressure in the port reaches the specified level.
      2. A01W3ZCE02
        Text in Illustration
        *1 Port A
        *2 Port B

        Open the fuel tank cap, close port A. Using a vacuum pump, apply vacuum to port B.

        OK