HV RELAY ASSEMBLY INSPECTION

PROCEDURE


  1. INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY


    1. Inspect SMRB


      1. A000869E01
        Text in Illustration
        *a

        Component without harness connected

        (Hybrid Battery Junction Block Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        A-1 (+) - S2-1 (CBI) Auxiliary battery voltage is not applied between terminals Q6-1 (SMRB) and Q6-2 (GND) 10 kΩ or higher
        A-1 (+) - S2-1 (CBI) Auxiliary battery voltage is applied between terminals Q6-1 (SMRB) and Q6-2 (GND) Below 1 Ω
      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Q6-1 (SMRB) - Q6-2 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω

        If the result is not as specified, replace the hybrid battery junction block assembly.

    2. Inspect SMRG


      1. A0005W4E01
        Text in Illustration
        *a

        Component without harness connected

        (Hybrid Battery Junction Block Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        f1-1 (-) - S3- 1 (CEI) Auxiliary battery voltage is not applied between terminals Q6-3 (SMRG) and Q6-2 (GND) 10 kΩ or higher
        f1-1 (-) - S3- 1 (CEI) Auxiliary battery voltage is applied between terminals Q6-3 (SMRG) and Q6-2 (GND) Below 1 Ω
      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Q6-3 (SMRG) - Q6-2 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω

        If the result is not as specified, replace the hybrid battery junction block assembly.

    3. Inspect SMRP


      1. A0004D7E01
        Text in Illustration
        *a

        Component without harness connected

        (Hybrid Battery Junction Block Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        f1-1 (-) - S3- 1 (CEI) Auxiliary battery voltage is not applied between terminals Q6-4 (SMRP) and Q6-2 (GND) 10 kΩ or higher
        f1-1 (-) - S3- 1 (CEI) Auxiliary battery voltage is applied between terminals Q6-4 (SMRP) and Q6-2 (GND) 28.5 to 31.5 Ω
      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Q6-4 (SMRP) and Q6-2 (GND) -40 to 80°C (-40 to 176°F) 112 to 274 Ω

        If the result is not as specified, replace the hybrid battery junction block assembly.