WATER PUMP WITH MOTOR INSTALLATION

PROCEDURE


  1. INSTALL INVERTER WATER PUMP ASSEMBLY


    1. A0005UQE03
      Text in Illustration
      *a Rib
      *b Alignment Mark
      *c 90°
      *d 2 to 7 mm (0.0787 to 0.276 in.)

      Connect the water hose to the inverter water pump assembly.

      Note


      • Make sure that the clip is positioned as shown in the illustration.

      • Make sure to align the alignment mark of the hose with the rib of the inverter water pump assembly.

      • Do not remove the pieces of cloth or plastic bags from the pipe and disconnected hose until installation.

    2. Install the inverter water pump assembly with the 3 bolts.

      Torque:
      6.1 N*m  { 62 kgf*cm, 54 in.*lbf }

      Note

      Do not hold the inverter water pump assembly by the connector when removing or installing it.

    3. Connect the connector to the inverter water pump assembly.

    4. A0003S9E03
      Text in Illustration
      *a Rib
      *b Alignment Mark
      *c 220°
      *d 2 to 7 mm (0.0787 to 0.276 in.)

      Connect the water hose to the inverter water pump assembly.

      Note


      • Make sure that the clip is positioned as shown in the illustration.

      • Make sure to align the alignment mark of the hose with the rib of the inverter water pump assembly.

      • Do not remove the pieces of cloth or plastic bags from the pipe and disconnected hose until installation.

  2. INSTALL INVERTER RESERVE TANK ASSEMBLY


    1. Temporarily install the inverter reserve tank assembly with the 2 bolts.

    2. A0008ZTE03

      Tighten the 2 bolts in the order shown in the illustration.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
  3. ADD COOLANT (for Inverter)

    Click here

  4. INSPECT FOR COOLANT LEAK (for Inverter)

    Click here